Altronix Maximal3 Access Power Controller

Technical Specification

Features:
  • Make: Altronix
  • Model code: Maximal3
  • Fail-Safe Operation: Yes
  • Voltage: 12 V DC
  • Dimensions mm: 26 x 19 x 6.25
Additional info:

This unit distributes and switches power to access control systems and accessories. It converts a 115VAC 60Hz input into sixteen (16) independently controlled 12VDC or 24VDC fuse protected outputs. These power outputs can be converted to dry form "C" contacts. Outputs are activated by an open collector sink or normally open (NO) dry trigger input from an Access Control System, Card Reader, Keypad, Push Button, PIR, etc. The unit will route power to a variety of access control hardware devices including: Mag Locks, Electric Strikes, Magnetic Door Holders, etc. Outputs will operate in both Fail-Safe and/or Fail-Secure modes. The FACP Interface enables Emergency Egress, Alarm Monitoring, or may be used to trigger other auxiliary devices. The fire alarm disconnect feature is individually selectable for any or all of the sixteen (16) outputs.

Read more
Make Altronix
Manufacturer Altronix
Category Access Control>Access control accessories
Model code Maximal3
Fail-Safe Operation Yes
Electrical Specifications Voltage: 12 V DC
Physical Specifications Dimensions mm: 26 x 19 x 6.25
Additional info This unit distributes and switches power to access control systems and accessories. It converts a 115VAC 60Hz input into sixteen (16) independently controlled 12VDC or 24VDC fuse protected outputs. These power outputs can be converted to dry form "C" contacts. Outputs are activated by an open collector sink or normally open (NO) dry trigger input from an Access Control System, Card Reader, Keypad, Push Button, PIR, etc. The unit will route power to a variety of access control hardware devices including: Mag Locks, Electric Strikes, Magnetic Door Holders, etc. Outputs will operate in both Fail-Safe and/or Fail-Secure modes. The FACP Interface enables Emergency Egress, Alarm Monitoring, or may be used to trigger other auxiliary devices. The fire alarm disconnect feature is individually selectable for any or all of the sixteen (16) outputs.
Download PDF version Download PDF version

Related Whitepapers

Three Essential Reasons To Upgrade Your Access Control Technology In 2022

10 Top Insights In Access, Cloud And More

Protecting Dormitory Residents and Assets

$common_vars['trending_topic_article_popup'][0]->title

Gallagher Brings Employee Badge In Apple Wallet To Customers Via Gallagher Command Center