Altronix ACM4CBE Multi-Output Access Power Controller
Technical Specification
- Make: Altronix
- Model code: ACM4CBE
- Fail-Safe Operation: Yes
- Voltage: 12 ~ 24 V AC/DC
- Dimensions mm: 216 x 191 x 89
Altronix ACM4CBE converts one (1) 12 to 24 volt AC or DC input into four (4) independently controlled Class 2 rated PTC protected power-limited auto-resettable outputs rated at 2A each. Outputs are activated by an open collector sink or normally open (NO) dry trigger input from an Access Control System, Card Reader, Keypad, Push Button, PIR, etc. ACM4CBE will route power to a variety of access control hardware devices including Mag Locks, Electric Strikes, Magnetic Door Holders, etc. Outputs will operate in both Fail-Safe and/or Fail-Secure modes. Units are designed to be powered by one common power source which will provide power for both the board operation and locking devices, or two (2) totally independent power sources, one (1) providing power for board operation and the other for lock / accessory power. The FACP Interface enables Emergency Egress, Alarm Monitoring, or may be used to trigger other auxiliary devices. The fire alarm disconnect feature is individually selectable for any or all of the four (4) outputs.
Read moreMake | Altronix |
---|---|
Manufacturer | Altronix |
Category | Access Control>Access control accessories |
Model code | ACM4CBE |
Fail-Safe Operation | Yes |
Electrical Specifications | Voltage: 12 ~ 24 V AC/DC |
Physical Specifications | Dimensions mm: 216 x 191 x 89 |
Accessories | Multi-Output Access Power Controller |
Additional info |
Altronix ACM4CBE converts one (1) 12 to 24 volt AC or DC input into four (4) independently controlled Class 2 rated PTC protected power-limited auto-resettable outputs rated at 2A each. Outputs are activated by an open collector sink or normally open (NO) dry trigger input from an Access Control System, Card Reader, Keypad, Push Button, PIR, etc. ACM4CBE will route power to a variety of access control hardware devices including Mag Locks, Electric Strikes, Magnetic Door Holders, etc. Outputs will operate in both Fail-Safe and/or Fail-Secure modes. Units are designed to be powered by one common power source which will provide power for both the board operation and locking devices, or two (2) totally independent power sources, one (1) providing power for board operation and the other for lock / accessory power. The FACP Interface enables Emergency Egress, Alarm Monitoring, or may be used to trigger other auxiliary devices. The fire alarm disconnect feature is individually selectable for any or all of the four (4) outputs. |
Download PDF version Download PDF version |
Related Whitepapers
Three Essential Reasons To Upgrade Your Access Control Technology In 2022
10 Top Insights In Access, Cloud And More
Protecting Dormitory Residents and Assets
The 2024 State Of Physical Access Trend Report
DownloadThe Security Challenges Of Data Centers
DownloadSecurity Practices For Hotels
DownloadSIA Identity and Biometrics Symposium
DownloadFacial Recognition
Download